Electrical Cables

This array of electrical cables can be availed in different design based choices to meet various application needs. Accessible in single core and multi core design options, these cables have high power transmission capacity. Operating temperature of these wires varies as per their design. Accessible in different length and width based choices, these cables have copper based conductor with excellent electrical conductivity level. Provided electrical cables can be installed quickly. As part of safety features, these high temperature proof cables are leakage protected. These have been quality checked as per their dielectric strength, mechanical properties and life span.

Mylar Shielded Unarmoured Instrumentation Cable

Armoured Instrumentation Cable

Foundation Fieldbus Cables


 

Thermocouple Cables

Device Net Cables

Mechanical Characteristics (Overall)
  • Operating Temperature Range: -20 degree C To +75 degree C
  • UL Temperature Rating: 75 degree C
  • Bulk Cable Weight: 108 lbs/1000 ft.
  • Max. Recommended Pulling Tension: 190 lbs.
  • Min. Bend Radius/Minor Axis: 4.800 in.

 

HR Cables

HR Cables are heat resistant wires that are suitable for applications that involve 400 degree C to 1200 degree C operating temperature range.  Available in single core and multi core design choices, these cables are 1.5 sq mm to 120 sq mm in length range. These flame retardant cables have excellent dielectric strength, good insulation properties and high mechanical strength. Moreover, HR Cables are water proof and rust protected which extend their service life. These cables can be availed at reasonable price from us.

  • Specifications : Suitable for 400deg. C to 1200 Deg. C
  • Range : 1.5 sq mm to 120 sqmm Single & Multicore.

Wind Power Cables

Speaker Cables

Mylar Shielded Armoured Instrumentation Cable

VFD Cables

PROPERTIES OF DIFFERENT SHEATH MATERIALS
  • Normal PVC Sheaths (ST-1)
  • These Cables propagate flame and emits dense fumes & toxic acid gas and Chlorine on burning.
  • Flame Retardant Sheath (ST-2 FR)
  • These Cables do not propagate flame and are self extinguishing. However emits dense fumes, toxic acid
  • gas and Chlorine on burning.
  • Flame Retardant Low Smoke Sheath (FRLS)
  • These Cables do not propagate flame and emit low amount of smoke and fumes. However, emits acid
  • gas on burning.
  • Low Smoke Zero Halogen Sheath (LSZH)
  • These Cables do not propagate flame, emit low amount of smoke and very negligible amount of acid gas on burning.

Shielded Cables

Specification

  • Construction Conductor : Annealed Copper / Tinned Copper wires according to class 1, 2 or 5 of IS : 8130 1984
  • Insulation : PVC / HR PVC / PE
  • Pairs : Twisted
  • Identification Pairs : Blue & white. Blue cores indicate pair identification by printed Numbers in case of Multi Pair / Multi Triad / Multi Quads.
  • Assembly : Concentric Layers.
  • Individual & Overall Screen : Aluminium Polyester tape of 0.05 mm / 0.06 mm / 0.075 mm thickness in continuous contact with annealed tinned copper drain wires of 0.5 sq.mm (with minimum 25 % overlap & 100 % coverage).
  • Outer Sheath : PVC / HR PVC / FRLSH PVC.
  • Standards : IEC 60332 1 Flame retardant , BS : 5308 (Part 2) & IS : 1554 (Part 1)

Screened Cables

Specification

  • Construction Conductor: Annealed Copper / Tinned Copper wires according to class 1, 2 or 5 of IS: 8130 1984
  • Insulation : PVC / HR PVC / PE
  • Pairs: Twisted
  • Identification Pairs: Blue & white. Blue cores indicate pair identification by printed Numbers in case of Multi-Pair / Multi Triad / Multi Quads.
  • Assembly: Concentric Layers.
  • Individual & Overall Screen : Aluminium Polyester tape of 0.05 mm / 0.06 mm / 0.075 mm thickness in continuous contact with annealed tinned copper drain wires of 0.5 sq.mm (with minimum 25 % overlap & 100 % coverage).
  • Outer Sheath: PVC / HR PVC / FRLSH PVC.
  • Standards : IEC 60332 1 Flame retardant , BS : 5308 (Part 2) & IS : 1554 (Part 1)

Control Net Cables

Modbus Cables


Ethrnet Cables

Composite Cables


Festoon Cables

Specification

  • Single Core Cables 1.5 sq mm to 300 sq mm
  • Multi Core Cable 37 Core X 1.5 sq mm
  • 4 Core X 150 sq mm

 